260
When rollback is activated the MX-2424's transport will locate backwards by the amount of time set as the Rollback
Length and stop. Rollback Length can be set in one-frame increments from 00:00:00:00 to 23:59:59:29. (Default is
00:00:10:00)
Rollback can be activated directly on the RC-2424 remote control unit by pressing <SHIFT> [19] then
LAST<ROLLBACK> [77].
A play head Jump can be activated on either the RC-2424 or the front panel of the MX-2424 by holding STOP [34]
and pressing either FAST FORWARD [33] or REWIND [32] to send you forward or backward using the amount
set up as the Rollback value.
270
With this Menu it is possible to toggle on or off the display of subframes in the LCD time display. A subframe is
th
1/100
of a frame. When toggled on it is possible to Trim Memory locations and Edit Points with subframe
accuracy. Points are always captured with subframe accuracy by pressing CAPT [16] even when subframe display
is turned off. (Default is Off.)
Menu Bank 300: MIDI
300
This Menu allows the MIDI Device ID of the MX-2424 to be set. It may become necessary to change this when the
MX-2424 is sharing the same MIDI Device ID as other equipment in a MIDI setup. (Default is 74)
Menu Bank 400: Input/Output
400
This Menu allows selection of input source for the first block of eight channels. The "/48k" designates the setup is
for recording at 44.1kHz, 48kHz and their associated pull up/down sample rates. When the 96kHz recording
software update is available menu choices will display options for 96kHz recording. Possible choices are:
Analog
Dig In
2CH In
Rollback Length
Display Subframe
MIDI Device ID
Inputs 1 – 8
/48k
When selected, input to tracks 1 – 8 is taken from inputs 1 – 8 of the analog I/O module
(IF-AN24) if installed.
When selected, input to tracks 1 – 8 is taken from inputs 1 – 8 of a digital I/O module
(IF-AE24, IF-AD24 or IF-TD24) if installed.
When selected, the dedicated stereo digital inputs are routed to channels 1 – 8 with the
Left signal going to the Odd tracks (1,3,5,7) and the Right signal going to the Even tracks
(2,4,6,8). It is then possible to record enable the desired Odd/Even pair of tracks for
stereo recording. (NOTE: When using this option it will be necessary to choose between
AES/EBU and SPDIF in Menu 462. and select 2CH In in Menu 002.)