HP 1850R - ProLiant - 128 MB RAM Troubleshooting Manual page 242

Proliant server troubleshooting guide
Hide thumbs Also See for 1850R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

POST Error Messages
Table C-13: 1700 Series POST Error Messages
Error Code
1783-Slot X Drive
Array Controller
Failure.
1783-Intelligent Drive
Array Controller
Failure
1784-Slot X Drive
Array Drive Failure.
The following SCSI
drive(s) should be
replaced:
SCSI Port Y:
SCSI ID Z:
C-62
Audible
Probable Source of
Beeps
Problem
None
Bad controller. If this
message is displayed
after Options ROMPaq is
run, problems may have
occurred while attempting
to flash the ROM.
None
Integrated Array
Controller firmware is
corrupt, or IAC is bad or
has failed.
None
Defective drive and/or
SCSI cables detected.
continued
Action
Reseat the array accelerator
module if detached. Try
reseating the controller in the
PCI slot. Otherwise, replace
the array controller.
1.
Be sure that integrated
array controller ROM
firmware is up to date.
2.
Replace I/O board.
Check for loose cables. Be
sure that all drives are fully
seated in drive bay slots.
Replace defective drive X
and/or cable(s).
HP Servers Troubleshooting Guide
continued

Advertisement

Table of Contents
loading