HP 1000 Series Installation Manual
Hide thumbs Also See for 1000 Series:

Advertisement

hp AlphaServer DS15
Series 10000 Rackmount Installation Guide
Order Number: EK-D1510-RM. B01
This Guide is for service providers and self-maintenance customers who
are installing an AlphaServer DS15 system into the 10000-series cabinet.
Hewlett-Packard Company

Advertisement

Table of Contents
loading

Summary of Contents for HP 1000 Series

  • Page 1 AlphaServer DS15 Series 10000 Rackmount Installation Guide Order Number: EK-D1510-RM. B01 This Guide is for service providers and self-maintenance customers who are installing an AlphaServer DS15 system into the 10000-series cabinet. Hewlett-Packard Company...
  • Page 2 HP shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided “as is” without warranty of any kind and is subject to change without notice.
  • Page 3 Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  • Page 4 Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user's authority to operate the equipment. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC rules and regulations.
  • Page 5 European Union Notice Products with the CE marking comply with the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community and if this product has telecommunication functionality, the R&TTE Directive (1999/5/EC). Compliance with these directives implies conformity to the following European Norms (in parentheses are the equivalent international standards and regulations): •...
  • Page 7: Table Of Contents

    Figure 1-2 Rack Bracket Location on the Rails ..............1-3 Figure 1-3 Installing the Rack Brackets................1-4 Figure 1-4 Attaching the Rackmount Ears................1-5 Figure 1-5 Inserting and Securing the Unit.................1-6 Figure 1-6 Securing Power ....................1-8 Tables Table 1 HP AlphaServer DS15 Documentation ............ix...
  • Page 8 viii...
  • Page 9: Preface

    Preface Intended Audience This manual is for service providers and self maintenance customers of the HP AlphaServer DS15 systems. Document Structure This manual uses a structured documentation design. Topics are organized into small sections, usually consisting of two facing pages. Most topics begin with an abstract that provides an overview of the section, followed by an illustration or example.
  • Page 11: Chapter 1 Rackmount Installation

    Rackmount Guidelines The hp AlphaServer DS15 is a three U unit and the PDU used is one U in size. This allows for a maximum of 13 systems in a 10000-Series cabinet.
  • Page 12: Unpack Rackmount Box

    Unpack Rackmount Box The rackmount box is one of three long boxes found in the unit’s shipping carton (see Figure 1-1 ). It contains these instructions, two rack brackets, screws, two front brackets for securing the unit in the rack, template, and a power cord bracket. Figure 1-1 Unpacking the Rackmount Kit MR0274A Determine Base Zero...
  • Page 13: Figure 1-2 Rack Bracket Location On The Rails

    Figure 1-2 Rack Bracket Location on the Rails Front Rack Rail Rear Rack Rail Locating Tab (in front) U-nut on Mounting Bracket Locating Tab (in front) Locating Tab (in front) Screw attachment point (in front) Locating Tab (in front) U-nut on Mounting Bracket Screw attachment point (in front) Left-side Rack Bracket Base 0...
  • Page 14: Install The Rack Rail Brackets

    Install the Rack Rail Brackets Figure 1-2 shows the correct positioning of the AlphaServer DS15 on the rack rails. To install the rack brackets, refer to Figure 1-3 and follow these steps. 1. Insert the longer rear tabs into the corresponding openings on the rear rack rail and push the bracket slightly toward the rear of the rack .
  • Page 15: Attach The Rackmount Ears

    Attach the Rackmount Ears 1. Align the three vertical holes located on the front edge of the system with the three holes on the rackmount ears (see Figure 1-4). 2. Using a Phillips screwdriver, screw the ears onto the system. Do not apply excessive force.
  • Page 16: Insert And Secure The Alphaserver Ds15

    Insert and Secure the AlphaServer DS15 1. Using both hands, place the AlphaServer DS15 onto the rails and push it back into the cabinet (see Figure 1-5). 2. Push the AlphaServer DS15 back into the rack. 3. Secure the AlphaServer DS15 into the cabinet by fastening the right and left front rackmount ears.
  • Page 17: Check Power And Secure Cables

    Check Power and Secure Cables 1. Remove the thumbscrew (see Figure 1-6). 2. Attach the power cord bracket with attached screw , turning it clockwise, but not tight. 3. Route the power cord over the back of the rail, into the cabinet side area. 4.
  • Page 18: For More Information

    Figure 1-6 Securing Power MR0553B For More Information Using a Web browser, you can access additional documentation at http://h18003.www1.hp.com/alphaserver/ 1-8 Series 10000 Rackmount Installation...