T

Technical Data

Technical Data
Model
Illumination/viewing system
Light-receiving element
Spectral separation device
Wavelength range
Wavelength pitch
Reflectance range
Light source
Measurement time
Minimum interval between measurements
Measurement/illumination area
Inter instrument agreement
Repeatability
Temperature drift
UV adjustment
Control method
Interface
Power
Size (WxHxD)
Weight
Operating temperature/humidity range
Standard accessories
Optional accessories
Specifications subject to change without notice
Konica Minolta - a synonym
for reliability and
expertise throughout the
paper industry
Konica Minolta manufactures its advanced measuring
instruments with meticulous care. Strict quality controls
ensure that each product rigorously
conforms with exacting industry standards.
For over 60 years, Konica Minolta has offered innovative,
affordable solutions that deliver solid value through
their reliability, durability, accuracy, precision and
repeatable performance.
CM-3630
Reflectance:d/0 (diffused illumination, 0-degree viewing)
Conforms to ISO 2469, JIS P8148, DIN 53145-1 and
DIN 53145-2 standards.
Silicon photodiode array (dual 40 elements)
Diffraction grating
360nm to 740nm
10nm
0 to 200%; resolution: 0.01%
Pulsed xenon lamps (x 3)
Approx. 1.5 seconds (for measurements of fluorescent colors,
at 9600 bps)
Approx. 4 seconds; when reflectance measured, approx. 5 seconds;
when fluorescent color
30mm/34mm
Mean ∆E*ab 0.2 based on 12BCRA Series II color titels compared to
values measured with master body
Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard
deviation within ∆E*ab 0.02 (condition; white calibration plate
measured 30 times at 10-second intervals)
Spectral reflectance: Within +/- 0.10%/°C Color difference:
Within ∆E*ab 0.05/°C
Instantaneous numerical adjustment
Directly connected to a computer
RS-232C format
100-240V AC, 50-60Hz 25W AC (with a dedicated AC adapter)
300 x 585 x 315 mm
15.5 Kg
13 to 33°C, relative humidity 80% or less (at 30°C) with no condensation
Operating temperature/humidity range of products for North America : 13 to 33°C,
relative humidity 80% or less (at 31°C) with no condensation
White calibration plate CM-A 133, Zero calibration box CM-A119,
AC Adapter AC-A12, AC Adapter AC-A21 (for Korea), RS-232C cable IF-A12,
Accessory Case CM-A117, Dust Cover CM-A118, Unit Driver CM-A108
Color Data Software PaperControl for CM-3630, Opacity jig CM-A134, RS-232C
cable IF-A10, IF-A11, IF-A13, IF-A14, IF-A15