Dell POWEREDGE 2950 Hardware Owner's Manual page 26

Dell computer accessories user manual
Hide thumbs Also See for POWEREDGE 2950:
Table of Contents

Advertisement

Table 1-6. LCD Status Messages (continued)
Code
Text
E2111
SBE Log Disable
Crd # DIMM ##
E2112
Mem Spare Crd #
DIMM ##
E2113
Mem Mirror Crd #
DIMM ## & ##
Fatal NB Mem CRC One of the connections in the
E2118
Fatal SB Mem CRC One of the connections in the
E2119
I1910
Intrusion
I1911
>3 ERRs Chk Log
26
About Your System
Causes
The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##"
represents the DIMM implicated
by the BIOS. If no memory riser
card is present, the "Crd #" string
is left out of the message.
The system BIOS has spared the
memory because it has
determined that the memory had
too many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If no
memory card is present, the "Crd
#" string is left out of the
message.
The system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the
DIMM pair implicated by the
BIOS. If no memory card is
present, the "Crd #" string is left
out of the message.
Fully Buffered DIMM (FBD)
memory subsystem link on the
Northbound side has failed.
FBD memory subsystem link on
the Southbound side has failed.
System cover has been removed.
LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
Corrective Actions
See "Troubleshooting System
Memory" on page 120.
See "Troubleshooting System
Memory" on page 120.
See "Troubleshooting System
Memory" on page 120.
See "Troubleshooting System
Memory" on page 120.
See "Troubleshooting System
Memory" on page 120.
Information only.
Check the SEL for details on the
events.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents