C
Channel Select / Sends On Fader
This checkbox enables you to specify whether or not the M7CL console and M7CL Editor are linked to each other
for the following operations:
• Selecting channels
• Switching between normal mode and SENDS ON FADER mode
• Switching between MIX and MATIRX in SENDS ON FADER mode
If you do not check the box, the M7CL console and M7CL Editor will operate independently.
D
Fast Sync
This allows synchronization to be speed up, reducing the time required. Check this box to enable the function.
E
Window Control From Console
This option determines whether or not using the USER DEFINED KEYS on the console enables you to remotely
open and close the M7CL Editor windows.
F

Level Meter

By disabling the meter function you can reduce the processing load caused by screen drawing and communica-
tion. This option specifies whether the level meter functionality will be enabled.
G
Confirmation
These check boxes specify whether a confirmation dialog box will appear when you store (Store Confirmation),
recall (Recall Confirmation), patch (Patch Confirmation), or make a patch change that would modify an existing
patch (Steal Patch Confirmation).
H
Administrator Password
Enter the Administrator password that was specified on the M7CL console. If this password is not entered cor-
rectly, it will not be possible to synchronize from M7CL Editor to the M7CL console.
I
Set Default
Press this button to use the settings currently specified in the System Setup dialog box as the default settings. The