Synchronizing M7CL Editor
When M7CL Editor starts up, the parameter settings on the console and the parameter settings in M7CL Editor may
be different. Therefore, you must first match the parameter settings on the console with those in M7CL Editor. This
operation is called "synchronization." Follow the steps below to synchronize M7CL Editor.
1 Select [Synchronize], then [Re-synchronize].
The following window opens.
2 Select whether you want to transfer your settings to M7CL
Editor, or vice versa.
At this time, the All Libs option determines whether or not Scene and
Library data is synchronized.
PC ➔ Console:
Transfers the current parameter settings in M7CL Editor to your console. On the M7CL-48ES,
the [Stage Box Setup] checkbox will appear. If you want to keep the Stage Box Setup setting of the M7CL-48ES
unit, remove the check from the checkbox.
Console ➔ PC:
Transfers the current parameter settings of your console to the M7CL Editor.
3 Click [OK].
Do not operate the console while synchronization is in progress.
If you use the "Recall" function in Studio Manager, all selected Editors in Studio Manager are synchro-
NOTE
nized with the corresponding devices.
Offline Edit Function
If you do not want to synchronize your console with M7CL Editor, select [Offline Edit] from the [Synchronization]
menu. To apply your off-line edits to your console, select [Re-Synchronize] from the [Synchronization] with the PC
-> Console option to synchronize the console with M7CL Editor.
The Offline Edit function is also activated when you click the [ONLINE]/[OFFLINE] button in the Master window.
Some effect parameters in the console change their displayed values depending on the sampling fre-
NOTE
quency. If you switch M7CL Editor from OFFLINE to ONLINE, displayed parameter values may change
because M7CL Editor loads the sampling frequency from the console and updates the display.

Other Functions

❏ Resetting to the default value (Ctrl( )+click)
Move the cursor to a control or a parameter value, then hold down the <Ctrl>(< >) key and click the mouse
button to reset the value to the default (e.g., to reset a pan setting to Center).
However, the channel faders and the send knobs and bar graphs can be set to – ∞ regardless of the default value.
❏ Ctrl( )+Shift+Click
Move the mouse cursor to a channel fader or to a send knob or bar graph, and click while holding down the
<Ctrl>(< >) key and <Shift> key to set the nominal value regardless of the default value.