Amplifier Units; Characteristic Data - Omron ZX-T Datasheet

Smart sensor high precision contact type zx-t series
Hide thumbs Also See for ZX-T:
Table of Contents

Advertisement

Amplifier Units

Item
Measurement period
Possible average count set-
tings (See note 1.)
Linear output (See note 2.)
Judgement outputs
(3 outputs: HIGH/PASS/
LOW)
Zero reset input, timing in-
put, reset input, judgement
output hold input
Function
Indicators
Power supply voltage
Current consumption
Ambient temperature
Temperature characteristic
Connection method
Weight (packed state)
Materials
Note 1. The response speed of the linear output is calculated as the measurement period
The response speed of the judgement outputs is calculated as the measurement period
2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.
3. Setting is possible via the monitor focus function.
4. A Calculating Unit (ZX-CAL2) is required.

Characteristic Data

Output Characteristics
Voltage/Current Output
ZX-TDS01T/-S04T/-S04T-L
4 V
0 V
−4 V
−0.5 mm
(−2 mm)
ON
High/Low output
OFF
Note: To prevent destroying the Sensor Head, both the high and low judgment outputs will light if 101% of the upper limit of the measurement
distance is reached.
ZX-T Series
ZX-TDA11
1 ms
1, 16, 32, 64, 128, 256, 512, or 1,024
Current output: 4 to 20 mA/F.S., Max. load resistance: 300 Ω
Voltage output: ±4 V (±5 V, 1 to 5 V (See note 3.)), Output impedance: 100 Ω
NPN open-collector outputs, 30 VDC, 30 mA max.
Residual voltage: 1.2 V max.
ON: Short-circuited with 0-V terminal or 1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
- Measurement value display- Present value/set value/output value display
- Display reverse- ECO mode - Number of display digit changes
- Sample hold- Peak hold- Bottom hold, peak-to-peak hold
- Self-peak hold - Self-bottom hold- Zero reset
- Initial reset- Direct threshold value setting- Position teaching
- Hysteresis width setting- Timing inputs- Reset input
- Judgement output hold input - Monitor focus- (A-B) calculations (See note 4.)
- (A+B) calculations (See note 4.) - Sensor disconnection detection
- Zero reset memory- Function lock- Non-measurement setting
- Clamp value setting- Scale inversion- Zero reset indicator
- Span adjustment- Warming-up display- Pressing force alarm
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), 7-segment
sub-digital display (yellow), power ON (green), zero reset (green), enable (green)
12 to 24 VDC ±10%, Ripple (p-p): 10% max.
140 mA max. (with Sensor connected), For 24-VDC power supply voltage: 140 mA max. (with Sensor connected)
Operating and storage: 0 to 50° C (with no icing or condensation)
0.03% F.S./° C
Prewired (standard cable length: 2 m)
Approx. 350 g
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate
Measurement distance (F.S)
Displacement direction
+
(Released)
(Pushed)
Center
0 mm
+0.5 mm
(+2 mm)
PNP open-collector outputs, 30 VDC, 30 mA max.
Residual voltage: 2 V max.
ON: Supply voltage short-circuited or supply voltage of
1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
×
(average count setting + 1).
×
20 mA
12 mA
4 mA
Displacement
ZX-TDA41
(average count setting + 1).
B-79