CPU Unit Function Block Specifications
FQM1 Flexible Motion Controllers
Item
Model
Max. number of I/O points
Program capacity (steps)
Data memory
Function blocks

Maximum num-

ber of definitions
Maximum num-
ber of instances
Inside comment
Function block
memory
program mem-
ory (Kbytes)
Comment files
(Kbytes)
Program index
files (Kbytes)
Variable tables
(Kbytes)
2-8-2

Operation of Timer Instructions

Selecting the Option
Not Selecting the
Option (Default)
Coordinator Module
FQM1-CM002
344 points (24 built-in
points + 320 points on
Basic I/O Units)
10K
32K words
128
256
256
64
64
64
There is an option called Apply the same spec as T0-2047 to T2048-4095 in
the PLC properties. This setting affects the operation of timers as described in
this section.
If this option is selected, all timers will operate the same regardless of timer
number, as shown in the following table.
Timer Operation for Timer Numbers T0000 to T4095
Refresh
When instruction is
The PV is refreshed each time the instruction is executed.
executed
If the PV is 0, the Completion Flag is turned ON. If it is not 0,
the Completion Flag is turned OFF.
When execution of all
All PV are refreshed once each cycle.
tasks is completed
Every 80 ms
If the cycle time exceeds 80 ms, all PV are refreshed once
every 80 ms.
If this option is not selected, the refreshing of timer instructions with timer
numbers T0000 to T2047 will be different from those with timer numbers
T2048 to T4095, as given below. This behavior is the same for CPU Units that
do not support function blocks. (Refer to the descriptions of individual instruc-
tion in the CS/CJ Series Instruction Reference for details.)
Motion Control Modules
FQM1-MMA22
20 built-in points
Description
Section 2-8
FQM1-MMP22
75