ID Tag with 8-/32-Kbyte Memory
Item
Model
Memory capacity
Memory type
Data backup time
(See note 1.)
Memory longevity
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Degree of protection
Vibration resistance
Shock resistance
Dimensions
Materials
Weight
Metallic compatibility
Note 1. Refer to the User's Manual (Cat. No. Z278 or Z279) for data backup time for temperatures of 70°C or higher.
2. The total Read or Write communication frequency is called the access frequency.
3. This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former JEM standard.
4. For details, refer to the User's Manual (Cat. No. Z278 or Z279).
Cylindrical Read/Write Antenna (Detachable Amplifier Unit Type)
Model
Item
Ambient operating temperature
Ambient storage temperature
Ambient operating humidity
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
Shock resistance
Appearance
Materials
Weight
Note 1. The degree of protection for the Connector is IP67/IP65. This OMRON in-house standard confirms resistance to cutting and other oils.
It is equivalent to the former JEM standard.
2. The Connector is not waterproof. This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former
JEM standard.
3. For details, refer to the User's Manual (Cat. No. Z278 or Z279).
V680-HAM42-DRT, V680-HAM91/-HAM81
6
V680-D8KF68
8,192 bytes (user area)
FRAM
10 years (at 70°C max.) after data is written
10 billion times per block at 85°C max. Access frequency (See note): 10 billion times
−20 to 85°C (with no icing)
−40 to 85°C (with no icing)
35 to 85%
IEC 60529, IP67
In-house standard for antenna oil resistance (former JEM standard equivalent to IP67g) (See note 2.)
10 to 500 Hz, 1.5-mm double amplitude at 100 m/s
11 minutes each
2
500 m/s
in X, Y, and Z directions 3 times each (18 times in total)
86 × 54 × 10 mm
Case: PBT resin
Filling: Epoxy resin
Approx. 50 g
No
V680-HS52-W
(Standard Cable, Waterproof
Connector)
−10 to 60°C (with no icing)
−25 to 75°C (with no icing)
35% to 95% (with no condensation)
20 MΩ min. (at 500 VDC) between the cable terminals and the case
1,000 VAC (50/60 Hz) for 1 minute between the cable terminals and the case with a current leakage of 5 mA max.
IP67 (IEC60529)
In-house standard for antenna oil
resistance (former JEM standard
equivalent to IP67g) (Read/Write
Antenna portion) (See note 1.)
10 to 500 Hz variable vibration, 1.5-mm double amplitude at 100 m/s
acceleration, with 10 sweeps in X, Y, and Z directions for 8 minutes each
2
500 m/s
in X, Y, and Z directions 3 times each (18 times in total)
M22 × 65 mm
ABS, brass, epoxy resin filling
Approx. 850 g (with 12.5-m cable)
32,744 bytes (user area)
2
acceleration with 10 sweeps in X, Y, and Z directions for
V680-HS52-R
(Flexible Cable, Non-waterproof
Connector)
IP67 (IEC60529)
In-house standard for antenna oil resistance (former JEM standard equivalent
to IP67g) (Read/Write Antenna portion) (See note 2.)
2
V680-D32KF68
V680-HS51
(Standard Cable, Non-waterproof
Connector)
10 to 2,000 Hz variable vibration,
1.5-mm double amplitude at 150 m/s
acceleration, with 10 sweeps in X, Y,
and Z directions for 15 minutes each
2
1,000 m/s
in X, Y, and Z directions
3 times each (18 times in total)
M12 × 35 mm
Approx. 55 g (with 2-m cable)
2