Download Print this page

Omron MY Datasheet page 10

General-purpose relay

Advertisement

Socket for MY
Track-mounted (DIN Track) Socket
Conforms to VDE 0106, Part 100
• Snap into position along continuous sections of any mount-
ing track.
• Facilitates sheet metal design by standardized mounting di-
mensions.
• Design with sufficient dielectric separation between termi-
nals eliminates the need of any insulating sheet.
Safety Standards for Sockets
Model
PYF08A-E, PYF08A-N
PYF14A-E, PYF14A-N
PYF14-ESN,
PYF14-ESS
Back-connecting Sockets
Specifications
Item
Pole
Screwless Clamp
2
Terminal Socket
4
Track-mounted
2
Socket
4
4
Back-connecting
2
Socket
4
Note: 1. The values given above are initial values.
2. The values for insulation resistance were measured at 500 V at the same place as the dielectric strength.
3. The maximum operating ambient temperature for the PYF08A-N and PYF14A-N is 55 C.
4. When using the PYF08A-N or PYF14A-N at an operating ambient temperature exceeding 40 C, reduce the current to 60%.
5. The MY2(S) can be used at 70 C with a carry current of 7 A.
10
General-purpose Relay
UL508
CSA22.2
UL508
CSA22.2
Model
PYF08S
10 A
PYF14S
5 A
PYF08A-E
7 A
PYF08A-N (see note 3)
7 A (see note 4)
PYF14A-E
5 A
PYF14A-N (see note 3)
5 A (see note 4)
PYF14-ESN/-ESS
12 A
PY08(-Y1)
7 A
PY08QN(-Y1)
PY08-02
PY14(-Y1)
3 A
PY14QN(-Y1)
PY14-02
MY New model
Standards
Carry current
Dielectric withstand
voltage
2,000 VAC, 1 min
2,000 VAC, 1 min
> 3 kV
1,500 VAC, 1 min
File No.
E87929
LR31928
E244189
LR225761
Insulation resistance
(see note 2)
Less than 1,000 M
1,000 M
min.
> 5 M
100 M min.