Operating Procedures

■ Operation in RUN Mode
Reset
Press the RESET/TEACH Key
value to 0. (Enabled when key protection is cleared.)
Measurement
value
Checking the Bank Number
Press the Shift Key
for 1 s min. during measurement to display
the bank number in the PV display. (The display will return to the
measurement value if there is no key operation for 5 seconds.)
Confirming and Setting Comparative Set Values
During measurement display, press the Mode Key
and OUT5. (With models that have an SV display, the comparative set values are displayed in the SV display.)
Measurement
value
Note: When a comparative set value is displayed, it can be changed using the Up Key
C-146
Up/Down Counting Meter
for 1 s min. to reset the counting
RESET
/TEACH
RESET
/TEACH
0
1 s min.
repeatedly to display the comparative set values in the order OUT1, OUT2, OUT3, OUT4,
Comparative set
Comparative set
value OUT1
value OUT2
No key operation for 5 s
No key operation for 5 s
K3NC

Bank Selection

• Switch between the comparative set values and the prescaling val-
ues for banks 1 to 4 using the BANK 1 and BANK 2 signals.
• The relationship between the BANK 1 and BANK 2 signals and the
bank numbers is shown in the following table.
Bank
BANK 1
number
1
OFF
2
ON
3
OFF
4
ON
Note: If the prescale value bank is set to OFF, then the prescaling val-
ue for each bank is fixed.
Comparative set
Comparative set
value OUT4
value OUT3
No key operation for 5 s
No key operation for 5 s
and Shift Key
BANK1
BANK2
COM
BANK 2
Comparat
Prescaling
ive set
value
value
OFF
sU1.**
ps1.**
OFF
sU2.**
ps2.**
ON
sU3.**
ps3.**
ON
sU4.**
ps4.**
Comparative set
value OUT5
No key operation for 5 s