Input Ranges - Omron E5GN Datasheet

Basic type digital temperature controller (48 x 24 mm)
Hide thumbs Also See for E5GN:
Table of Contents

Advertisement

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal Inputs)
Input
Platinum resistance
Type
thermometer
Name
Pt100
JPt100
2300
1800
1700
1600
1500
1400
1300
1200
1100
1000
850
900
800
700
600
500.0
500.0
500
400
300
200
100.0
100.0
100
0
0.0
0.0
−100.0
−200.0
−200 −199.9
−199.9
Setting
0
1
2
3
number
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-1995, IEC 584-1
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
W: W5Re/W26Re, ASTM E988-1990
JPt100: JIS C 1604-1989, JIS C 1606-1989
Pt100: JIS C 1604-1997, IEC 751
PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
Models with Analog Inputs
Input Type
Input specification
4 to 20 mA
Usable in the following ranges by scaling:
Setting range
−1999 to 9999, −199.9 to 999.9, −19.99 to 99.99 or −1.999 to 9.999
Setting number
0
Shaded settings are the default settings.
K
J
T
1300
850
500.0
400.0
400
400.0
−20.0 −100 −20.0
−200
−200 −199.9 −200
4
5
6
7
8
9
10
Current
0 to 20 mA
1 to 5 V
1
2
Thermocouple
E
L
U
N
R
S
1700 1700
1300
850
600
400
400.0
0
0
−100
−200 −199.9 −200
11
12
13
14
15
16
17
Voltage
0 to 5 V
0 to 10 V
3
4
Basic type digital temperature controller
Infrared temperature
sensor
115
60 to
PL
10 to
to
B
W
120
II
70°C
165
°C
°C
2300
1800
1300
120
165
90
100
0
0
0
0
0
18
24
25
19
20
21
E5GN
Analog
input
140
0 to
to
260
50 mV
°C
Usable
in the
following
ranges
by
scaling:
−1999 to
9999 or
−199.9
to 999.9
260
0
22
23
7

Advertisement

Table of Contents
loading

Table of Contents