Omron E5 Getting Started Manual page 33

Digital temperature controllers
Hide thumbs Also See for E5:
Table of Contents

Advertisement

Installation
E5AN/EN
Terminal Cover
(E53-COV16)
Waterproof packing
1,2,3...
Mounting
Bracket
Panel
E5AN
Mounting to the Panel
1. For waterproof mounting, waterproof packing must be installed on the
Controller. Waterproofing is not possible when group mounting several
Controllers. Waterproof packing is not necessary when there is no need for
the waterproofing function.
2. Insert the E5AN/E5EN into the square mounting hole in the panel (thick-
ness: 1 to 8 mm). Attach the Mounting Brackets provided with the product
to the mounting grooves on the top and bottom surfaces of the rear case.
3. Use a ratchet to alternately tighten the screws on the top and bottom
Mounting Brackets little by little to maintain balance, until the ratchet turns
freely.
Mounting the Terminal Cover
Slightly bend the E53-COV16 Terminal Cover to attach it to the terminal block
as shown in the following diagram. The Terminal Cover cannot be attached in
the opposite direction.
Slightly bend the
E53-COV16
Terminal Cover in
the direction shown
by the arrows to
attach it to the
terminal block.
Enlarged Illustration of Terminal Section
Mounting
Bracket
Terminal Cover
(E53-COV16)
Waterproof packing
E5EN
Section 2-1
Panel
21