Long Distance Square Inductive Proximity Sensor
E2Q2
• Terminal Housing
• Active face direction changeable
• Easy to install and same mounting dimensions as
a standard style electro-mechanical limit switch
• Integrated short circuit and reverse polarity protec-
tion
• Robust body with stainless steel screws
Ordering Information
DC type
Sensing
Connection
distance
20 mm
shielded
30 mm
Terminals
non-shielded
40 mm
non-shielded
# = H: terminal conduit M20x1,5
U: terminal conduit 1/2" NPT
Sensing
Connection
distance
15 mm
shielded
Terminals
30 mm
shielded
# = H: terminal conduit M20x1,5
U: terminal conduit 1/2" NPT
Sensing
Connection
distance
15 mm
Terminal
shielded
conduit ½" NPT
Weld-Field Immune AC type (100mT)
Sensing
Connection
distance
15 mm
Terminal
shielded
conduit ½" NPT
E2Q2
Square Proximity Sensor
Active
face
NPN
PNP
NPN
Changeable
PNP
NPN
PNP
AC type
Active
face
AC
Changeable
AC
Weld-Field Immune DC type (100mT)
Active
face
Changeable
PNP
Active
face
Changeable
AC
Output
NO
E2Q2-N20E1-H
E2Q2-N20E3-#
E2Q2-N20F1-H
E2Q2-N20F3-#
E2Q2-N30ME3- #
E2Q2-N30MF3-#
E2Q2-N40ME3- #
E2Q2-N40MF3-#
Output
NO
E2Q2-N15Y4-#
E2Q2-N30MY4- #
Output
NO
E2Q2-N15F1-51
Output
NO
E2Q2-N15Y4-51
NO + NC
NO or NC
NO + NC
NO or NC
D-69

Advertisement

loading

Summary of Contents for Omron E2Q2

  • Page 1 E2Q2 Square Proximity Sensor • Terminal Housing • Active face direction changeable • Easy to install and same mounting dimensions as a standard style electro-mechanical limit switch • Integrated short circuit and reverse polarity protec- tion • Robust body with stainless steel screws...
  • Page 2 Ambient humidity 35 to 95% RH Influence of temperature ± 10% max. of Sn at 23° in temperature range of -25° to 70°C Dielectric strength 1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case Electromagnetic compatibility EMC...
  • Page 3 35 to 95% RH Influence of temperature ± 10% max. of Sn at 23° in temperature range of -25° to 70°C 1.500 VAC / 2500 VAC (E2Q2-...-H), 50/60 Hz for 1 min. between current carry parts and Dielectric strength case...
  • Page 4: Output Circuit Diagram

    Output circuit mode Non-sensing zone Sensing zone Brown Sensing object Blue Proximity Sensor main Brown circuits NO or NC E2Q2-N15Y4-51 White Yellow indicator Operation Indicator Control output NO (yellow) Control output NC Note: Only one load allowed! D-72 Inductive Sensors...
  • Page 5: Dimensions (Unit: Mm)

    Dimensions (Unit: mm) E2Q2-...-H type E2Q2-...-U and -51 type M20x1,5 ½“ NPT E2Q2 D-73...
  • Page 6 = Current consumption of the Sensor = Load current If the MY Relay, which operate at 24 VDC, is used as a load for example, a maximum of two Proximity Sensors can be connected to the load. A minimum of three Sensors with current outputs can be connected in (parallel connec- parallel.
  • Page 7 Do not connect an AC power supply to any DC model. If AC power (100 VAC or more) is supplied to the sensor, it may ex- plode or burn.
  • Page 8: Maintenance And Inspection

    Never disassemble or repair the Sensor. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D01E-EN-02 In the interest of product improvement, specifications are subject to change without notice.

This manual is also suitable for:

E2q2-n20e1-hE2q2-n20f1-hE2q2-n20e3 seriesE2q2-n20f3 seriesE2q2-n30me3 seriesE2q2-n30mf3 series ... Show all