Omron D40A-G9SX-NS Brochure page 8

Compact non-contact door switch/flexible safety unit
Hide thumbs Also See for D40A-G9SX-NS:
Table of Contents

Advertisement

Characteristics
Item
Over-voltage category
(IEC/EN 60664-1)
Operating time (OFF to ON state) *1
Response time (ON to OFF state) *1
ON-state residual voltage
OFF-state leakage current
Maximum wiring length of safety
input, logical AND connection
input, and Non-contact Door Switch
input
Reset input time
(Reset button pressing time)
Accuracy of OFF-delay time *5
Between logical AND
connection terminals,
and power supply input
terminals and other
input and output
Insulation
terminals connected
resistance
together
Between all terminals
connected together and
DIN rail
Between logical AND
connection terminals,
and power supply input
terminals and other
input and output
terminals connected
together
Between all terminals
Dielectric
connected together and
strength
DIN rail
Between different poles
of outputs
Between relay outputs
connected together and
other terminals
connected together
Vibration resistance
Destruction
Shock
resistance
Malfunction
Electrical
Durability
Mechanical
Ambient operating temperature
Ambient operating humidity
Terminal tightening torque
Weight
*1. When two or more Units are connected by logical AND, the operating time and response time are the sum total of the operating times and
response times, respectively, of all the Units connected by logical AND.
*2. Represents the operating time when the safety input turns ON with all other conditions set.
*3. Represents the operating time when the logical AND input and the Non-contact Door Switch input turn ON with all other conditions set.
*4. This does not include the operating time or response time of G9SX-NS@ that are connected.
*5. This does not include the operating time or response time of internal relays in the G9SX-EX-@.
*6. The failure detection time for 24 V short-circuit failure on the input to Non-contact Door Switches is 35 ms max.
If using the Switch for an application other than as a Door Switch, calculate the safe distance using a failure detection time of 35 ms.
Model
G9SX-NS202-@
II
100 ms max. (Logical AND
connection input ON and
Non-contact Door Switch input
ON)
15 ms max. (Logical AND
connection input: OFF)
20 ms max. (Non-contact Door
Switch input OFF) *6
3.0 V max. (safety output, auxiliary output)
0.1 mA max. (safety output, auxiliary output)
100 m max. (External connection impedance: 100 Ω max. and 10 nF max.)
100 ms min.
---
20 MΩ min. (at 100 VDC)
500 VAC for 1 min.
10 to 55 to 10 Hz, 0.375 mm single amplitude (0.75 mm double amplitude)
2
300 m/s
2
100 m/s
−10 to 55°C (no icing or condensation)
25% to 85%
0.5 N·m (For the G9SX-NS@-RT (with screw terminals) only)
Approx. 125 g
G9SX-NSA222-T03-@
50 ms max. (Safety input: ON) *2
100 ms max. (Logical AND
connection input ON and
Non-contact Door Switch input ON)
*3
15 ms max. (Safety input OFF and
logical AND connection input OFF)
20 ms max. (Non-contact Door
Switch input: OFF) *6
Within ±5% of the set value
---
---
---
Approx. 200 g
D40A/G9SX-NS
G9SX-EX-@
II (Relay outputs 13 to 43 and 14
to 44: III)
30 ms max. *4
10 ms max. *4
Within ±5% of the set value
---
100 MΩ min.
(at 500 VDC)
---
1,200 VAC for 1 min
2,200 VAC for 1 min
100,000 cycles min. rated load,
switching frequency: 1,800
cycles/hour)
5,000,000 cycles min. (switching
frequency: 7,200 cycles/hour)
Approx. 165 g
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

D40aG9sx-ns

Table of Contents