Wiring of Inputs and Outputs
G9SX-NS202-@
Terminal
Signal name
name
Power supply
A1, A2
input
Non-contact
D1, D2,
Door Switch input
D3, D4
Feedback/reset
T31, T32,
input
T33
Logical AND
T41, T42
connection input
Instantaneous
S14, S24
safety output
Logical AND
connection
L1
output
Auxiliary monitor
X1
output
Auxiliary error
X2
output
Description of operation
Connect the power source to the A1 and A2
terminals.
All Non-contact Door Switch inputs connected to the
G9SX-NS@ must be ON as a required condition for
the safety outputs to be ON. Otherwise the safety
outputs cannot be in the ON state.
To set the safety outputs in the ON state, the ON state
signal must be input to T33. Otherwise the safety
outputs cannot be in the ON state.
To set the safety outputs in the ON state, the signal
input to T32 must change from the OFF state to the
ON state, and then to the OFF state. Otherwise the
safety outputs cannot be in the ON state.
A logical AND connection means that one unit (Unit
A) outputs a safety signal "a" to a subsequent unit
(Unit B) and Unit B calculates the logical AND (i.e.,
outputs the AND) of the signal "a" and safety signal
"b", which is input to Unit B.
Thereby the logic of the safety output of Unit B is
(AND). (An AND of inputs "a" and "b" is output.)
To set the safety outputs of the subsequent Unit in the
ON state, its logical AND connection preset switch
must be set to AND (enable) and the high signal must
be input to T41 of the subsequent unit.
Turns ON/OFF according to the state of the safety
inputs, Non-contact Door Switch inputs, feedback/
reset inputs, and logical AND connection inputs.
During OFF-delay state, the Instantaneous safety
outputs are not able to turn ON.
Outputs a signal of the same logic and at the same
time as the instantaneous safety outputs.
Outputs a signal of the same logic and at the same
time as the instantaneous safety outputs.
Outputs when the error indicator is lit or flashing.
D40A/G9SX-NS
Wiring
Connect the power supply plus (24 VDC) to the A1
terminal.
Connect the power supply minus (GND) to the A2
terminal.
White
Black Brown
D1
D2
D3
Auto reset
Reset
Manual reset
Switch
Input a
Unit A
G9SX-NS/NSA
L1 A2
Logical AND connection sig.
Output (a)
(1st layer)
Input b
Unit B
T41 T42
G9SX-NS/NSA
L1
A2
Logical AND connection sig.
Output (a&b)
(2nd layer)
T41 T42
G9SX-NS/NSA
L1
A2
Next unit (5 layers max.)
Keep these outputs open when not used.
Keep these outputs open when not used.
Keep these outputs open when not used.
Keep these outputs open when not used.
Blue
D4
Feedback loop
KM
+24 V
T31
T32
T33
Feedback loop
KM +24 V
T31
T32
T33
Next unit (4 unit max.)
T41 T42
G9SX-NS/NSA
Next unit (4 unit max.)