Omron CS1D DUPLEX SYSTEM - 10-2009 Operation Manual page 573

Cs1d duplex system
Table of Contents

Advertisement

Auxiliary Area Allocations
Addresses
Name
Word
Bit
A502 to
A50200
Special I/
A507
to
O Unit
A50715
Restart
Bits
A508
A50809
Differenti-
ate Moni-
tor
Com-
pleted
Flag
A50811
Trace Trig-
ger Moni-
tor Flag
A50812
Trace
Com-
pleted
Flag
A50813
Trace
Busy Flag
A50814
Trace
Start Bit
A50815
Sampling
Start Bit
A510 to
A51000
Start-up
A511
to
Time
A51115
Function
Turn these bits ON to restart (initialize)
the Special I/O Unit with the corre-
sponding unit number. Bits A50200 to
A50715 correspond to unit numbers 0
to 95.
When a restart bit is turned ON, the
corresponding Special I/O Unit Initializ-
ing Flag (A33000 to A33515) will be
turned ON. Both the restart bit and ini-
tializing flag will be turned OFF auto-
matically when initialization is
completed. Do not turn the bit OFF
from a Programming Device or the lad-
der program.
ON when the differentiate monitor con-
dition has been established during exe-
cution of differentiation monitoring.
(This flag will be cleared to 0 when dif-
ferentiation monitoring starts.)
ON when a trigger condition is estab-
lished by the Trace Start Bit (A50814).
OFF when the next Data Trace is
started by the Sampling Start bit
(A50815).
ON when sampling of a region of trace
memory has been completed during
execution of a Trace.
OFF when the next time the Sampling
Start Bit (A50815) is turned from OFF
to ON.
ON when the Sampling Start Bit
(A50815) is turned from OFF to ON.
OFF when the trace is completed.
Turn this bit from OFF to ON to estab-
lish the trigger condition. The offset
indicated by the delay value (positive or
negative) determines which data sam-
ples are valid.
When a data trace is started by turning
this bit from OFF to ON from a Pro-
gramming Device, the PLC will begin
storing data in Trace Memory by one of
the three following methods:
1) Data is sampled at regular intervals
(10 to 2,550 ms).
2) Data is sampled when TRSM(045) is
executed in the program.
3) Data is sampled at the end of every
cycle.
The operation of A50815 can be con-
trolled only from a Programming
Device.
These words contain the time at which
the power was turned ON. The con-
tents are updated every time that the
power is turned ON. The data is stored
in BCD.
A51000 to A51007: Second (00 to 59)
A51008 to A51015: Minute (00 to 59)
A51100 to A51107: Hour (00 to 23)
A51108 to A51115: Day of month (01 to
31)
Settings
Status
Status at
after
startup
mode
change
OFF to ON:
Held
Cleared
Restart
ON to OFF:
Restart com-
pleted
Turned OFF by
the system
when the Unit
has been
restarted.
ON: Monitor
Held
Cleared
condition
established
OFF: Not yet
established
ON: Trigger
Held
Cleared
condition
established
OFF: Not yet
established or
not tracing
ON: Trace
Held
Cleared
completed
OFF: Not trac-
ing or trace in
progress
ON: Trace in
Held
Cleared
progress
OFF: Not trac-
ing (not sam-
pling)
ON: Trace trig-
Held
Cleared
ger condition
established
OFF: Not
established
OFF to ON:
Held
Cleared
Starts data
trace (sam-
pling)
Turned ON
from Program-
ming Device.
See Function
Held
See
column.
Function
column.
Appendix B
Timing
Related
Flags,
Settings
---
A33000 to
A33515
---
---
---
---
------
---
---
---
---
---
---
---
When
---
power is
turned
ON
537