17 Selecting the sensitivity range (Att)

Condenser microphones and dynamic microphones require different
sensitivity settings. The SKP 30 is therefore equipped with two
different with sensitivity ranges tailored for each type of microphone.
This function switches in a 20 dB attenuation for condenser
microphones.
Select the "Att" menu by pressing the
appears on the display; after a short pause the current setting –
i.e. "Att OFF" or "Att On" – is displayed.
With the / buttons you can now switch between two
different sensitivity ranges.
: Sensitivity range 1 for dynamic microphones
– "Att OFF" flashes on the display
: Sensitivity range 2 for condenser microphones
– "Att On" flashes on the display.
Press the
SET
then switches back to the standard display.