Smeg SI 3642B Manual page 24

Table of Contents

Advertisement

HOB TYPE
(CM)
Carefully read the connection layout plate underneath the appliance or around the power cable.
Use H05V2V2-F cables resistant to at least 90°C.
The aforementioned power cables are sized taking into account the coincidence factor (in compliance
with standard EN 60335-2-6).
50
Instructions for the installer
POSSIBLE CONNECTION
TYPES
380
-
415
V
3N~ 5-pole
380
-
415
V
2N~ 4-pole
220
-
240
V
3~
220
-
240
V
1N~ 3-pole
220
-
240
V
1N~ 3-pole
CABLE TYPE
(if not present)
5 x 2.5 mm²
4 x 2.5 mm²
4-pole
4 x 2.5 mm²
3 x 4 mm²
3 x 6 mm²
H05V2V2-F
H05V2V2-F
H05V2V2-F
H05V2V2-F
H05V2V2-F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Si3321bSi3733bSi3950b3642b

Table of Contents