Instructions for the installer

10.2 Cable replacement
Should the supply cable need replacing,
remove the back guard by unscrewing the
screws to gain access to the terminal.
Replace the cable. The cable cross-section
must be no less than 1.5 mm² (3 x 1.5) (see
10.1 Electrical connection).
Make sure that the cables (for the oven or any
hob) follow the best route in order to avoid any
contact with the oven.
WARNING: The tightening torque of the screws of the terminal supply wires
must be 1.5 - 2 Nm.
10.3 Inserting the fastening bushings
To fasten the appliance correctly to the
unit, insert the bushings provided onto
the front (as shown in the figure).
Once the appliance is in place, fasten it
to the unit using the screws. The
bushing enables the screw to be
angled by approximately 30°.
After fastening the appliance, cover the
bushing with the caps provided.