Instructions for the installer

2. INSTALLATION

2.1 Electrical connection
Make sure the voltage and the cross-section of the power cord match
the specifications indicated on the identification plate positioned on the
frame of the oven door. Do not remove this plate for any reason.
The appliance must be connected to earth in compliance with electrical
system safety regulations.
If a plug and socket connection is being used, make sure that the plug
and socket are compatible. Do not use of adapters and shunts as these
could cause overheating and risk of burns.
If a fixed connection is being used, fit the power line with an omnipolar
circuit breaker with a contact opening gap equal to or greater than 3
mm, in an easily accessible position close to the appliance.
For operation on 220-240V
: use an
H05RR-F / H05RN-F type three-core cable
2
(3 x 1.5 mm
).
The end to be connected to the appliance
must have an earth wire (yellow-green) at
least 20 mm longer than the others.
The manufacturer cannot be held liable for damage to persons or
things caused by failure to observe the above instructions or deriving
from tampering with any part of the appliance.