F-33
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
• Perform High Frequency Disable Procedure.
____________________________________________________________________
MACHINE LOADED TO 150 AMPS AT
16VDC.
This is the typical AC output voltage wave-
form generated from a properly operating
machine. Note that each vertical division
represents 10 volts and that each horizontal
division represents 2 milliseconds in time.
The machine was loaded with a resistance
grid bank. The grid load meters read 150
amps and 16VDC
Note: Scope probes connected at machine
output terminals: (+) probe to electrode, (–)
probe to work.
TROUBLESHOOTING & REPAIR
AC TIG MODE
CAUTION
10 V
SQUARE WAVE TIG 175
2 ms
SCOPE SETTINGS
Volts/Div................................10 V/Div.
Horizontal Sweep .................2 ms/Div.
Coupling .........................................DC
Trigger .....................................Internal
F-33
0 V