FAULTS
When a fault occurs, the trowel's horn will begin a repeating
cycle of 5 beeps every 30 seconds. The amber LEDs on
the diagnostic display will turn ON (Figure 57), and the
Check Engine icon will be shown on the display. When
this happens:
1. Press the button on the right side of the display to view
the active fault code (Figure 58).
CHECK ENGINE
1730
AMBER LEDs
RIGHT-SIDE
Figure 57. Diagnostic Display (Active Fault)
Figure 58. Diagnostic Display (Fault Code Screen)
2. Shut down the engines and correct the problem.
Until the fault has been cleared and machine power has
been restored, the horn's beeping cycle will continue to
repeat while the engines are running or the ignition key is
in the ON position.
PAGE 48 — MD105 RIDE-ON TROWEL • OPERATION MANUAL — REV. #0 (03/29/24)
ICON
3
RPM
12
V
45
°C
0
Kpa
(ON)
BUTTON

TROUBLESHOOTING

NOTICE
NEVER disable or disconnect the horn. Serious
damage to the trowel may occur as a result.
Fault codes shown on the diagnostic display are primarily
for machine faults. The only engine faults that are shown
on the display are related to engine oil temperature. For a
complete list of fault codes that are shown on the display,
see Table 10.
Table 10. Diagnostic Display Fault Codes
Name
SPN
LH Engine Oil
175
Temp. Warning
LH Engine Oil
175
Temp. Alarm
RH Engine Oil
1135
Temp. Warning
RH Engine Oil
1135
Temp. Alarm
LH Hyd. Pressure
521110
Low Alarm
LH Hyd. Pressure
521110
Low Warning
LH Hyd. Pressure
521110
High Stage 1
RH Hyd. Pressure
521111
Low Alarm
RH Hyd. Pressure
521111
Low Warning
RH Hyd. Pressure
521111
High Stage 1
LH Rotor Speed
521127
Fault
RH Rotor Speed
521128
Fault
Pedal A Fault
521131
LH Fan Fault
521139
RH Fan Fault
521140
LH Pump Coil
521152
Fault
RH Pump Coil
521153
Fault
Pedal B Fault
521156
Pedal Sync Fault 521237
FMI Description
15
LH Block Temp
(SPN 110 > 120°C)
0
LH Block Temp
(SPN 110 > 125°C)
15
RH Block Temp
(SPN 110 > 120°C)
0
RH Block Temp
(SPN 110 > 125°C)
1
LH Loop Pressure < 5 bar
17
LH Loop Pressure < 15 bar
0
LH Loop Pressure > 400 bar
1
RH Loop Pressure < 5 bar
17
RH Loop Pressure < 15 bar
0
RH Loop Pressure > 400 bar
11
No Speed Detected
W\RH Speed > 30
11
No Speed Detected
W\LH Speed > 30
11
11
11
11
11
11
11

Advertisement