Electrical Requirements - KitchenAid KCIG556JBL Installation Instructions Manual

24" (65 cm), 30" (78.2 cm) and 36" (92.2 cm) electric induction cooktop
Table of Contents

Advertisement

Available languages

Available languages

Table 1
Model
24"
20
30"
20
36"
20
NOTE: After you make the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
If cabinet has a drawer, a 5
1
countertop to the top of the drawer (or other obstruction) in base
cabinet is required.
Flush Installation - Frameless
1/4" (6 mm)
1³⁄₁₆" (3 cm)
Model
X
24"
25
/
" (65.5 cm)
13
16
30"
31" (78.7 cm)
36"
36
/
" (92.7 cm)
1
2
CUT OUT (range)
F
J
3
/
7
/
" (51.7 cm)
21
" (55.6 cm)
8
8
/
/
3
" (51.7 cm)
29
9
" (75.1 cm)
8
16
/
/
3
9
" (51.7 cm)
35
" (90.3 cm)
8
16
" (13 cm) depth clearance from the
8
Y
21
/
" (54.5 cm)
7
16
21
/
" (54.5 cm)
7
16
21
/
" (54.5 cm)
7
16
X
Y
Detail A
Glass radius 6 mm

Electrical Requirements

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
cooktop is properly grounded.
It is not recommended to have a fuse in the neutral or ground
circuit.
Make sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical Code,
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No.O-M91-latest
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A
R8 ± 0.5
R5.5 ± 0.5
5