Performance
Data Sheet
(con't)
2
Total Defense (TD)
The Total Defense has been tested according to NSF/ANSI 42 and 5 for the reduction of
the substances listed below. The concentration of the indicated substances in the water
entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 42 and 5.
Substance Removal
1
Substance
Influent
Challenge
Concentration
mg/L
Standard 42
Chlorine
2.0 mg/L + 10%
Chloramines
.0 mg/L + 10%
Particulate
at least 10,000
(0.5 - < um) Class I
particles/mL
Standard 5
MTBE
0.015 + 20%
Cyst t
Minimum
50,000/L
Turbidity
11 mg/L + 1
NTU
Lead (pH 6.5)
0.15 mg/L +
10%
Lead (pH 8.5)
0.15 mg/L +
10%
Mercury (pH 6.5)
0.006 mg/L +
10%
Mercury (pH 8.5)
0.006 mg/L +
10%
Chloroform (VOC surro-
0.00 mg/L +
gate chemical)
10%
Flow Rate = 0.5 gpm (1.89 Lpm)
Capacity = 1,000 gallons (786 L)
t Based on the use of microspheres or Cryptosporidium parvum oocysts
Testing was performed under standard laboratory conditions, actual performance may vary
Organic Chemicals Included in Surrogate Testing:
Applies to Total Defense (TD) only
Maximum
Reduction
Permissible
Require-
Product
ments
water Con-
centration
mg/L
>50%
0.5 mg/L
>85%
0.005 mg/L
69%
99.95%
0.5 NTU
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.015 mg/L
Minimum
Average
Reduction
Reduction
97.6%
98.0%
97.6%
98.0%
99.9%
99.9%
74.6%
8.%
99.95%
99.99%
96.6%
98.0%
99.%
99.%
99.%
99.%
96.6%
96.6%
72.4%
95.4%
95.2%
91.0%