Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water Systems Owner's Manual page 26

Advanced drinking water systems
Table of Contents

Advertisement

Performance
Data Sheet
(con't)
26
AS3
The AS has been tested according to NSF/ANSI 5 for the reduction of the substances
listed below. The concentration of the indicated substances in the water entering the
system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 5. Conforms to NSF/ANSI Standard 5 for
arsenic (trivalent and pentavalent) reduction. See Arsenic Fact section for an explanation
of reduction performance.
Substance
Influent
Challenge
Concentration
mg/L
Standard 5
Trivalent Arsenic pH 6.5 0.050 + 10%
Trivalent Arsenic pH 8.5 0.050 + 10%
Pentavalent Arsenic
0.050 + 10%
Flow Rate = 0.05 gpm (0.1 Lpm)
Capacity = 1000 gallons (786 L)
1000 gallon capacity is only for use with PID
Testing was performed under standard laboratory conditions, actual performance may vary
Maximum
Reduction
Permissible
Require-
Product
ments
water Con-
centration
mg/L
0.010
0.010
0.010
Minimum
Average
Reduction
Reduction
94.9%
98.0%
97.4%