Instructions for the installer

2. INSTALLING THE APPLIANCE

It is the law that all gas appliances are installed by competent persons.
Corgi gas installers are approved to work to safe and satisfactory
standards. All gas installation, servicing and repair work must be in
accordance with the gas safety regulations 1984 (installation and use) as
amended 1990.
It can be installed against walls one of which is higher than the worktop
surface, at least 50 mm from the side of the appliance, as shown in the
installation class drawings A and B. Wall units or extractor hoods installed
above the appliance's work-top must be at least 750 mm above it.
A
B
Built-in appliance
Free-standing installation
2.1 Electrical connection
Make sure the voltage and the cross-section of the power supply line
match the specifications indicated on the identification plate positioned in
the storage compartment.
Do not remove this plate for any reason.
The plug at the end of the power cable and the wall socket must be the
same type (conforming to regulations in force). Check that the power line
is adequately grounded. Do not use reducers, adapters or shunts.
Fit the power supply line with a multipolar cut-out device with a contact
opening gap equal to or greater than 3 mm in an easily accessible
position close to the appliance.
If the power cable is replaced, the wire
section on the new cable must not be
2
less than 1.5 mm
(3 x 1.5 cable),
keeping in mind that the end to be
connected to the hob must have the
ground wire (yellow-green) longer by
at least 20 mm. Use only the special
cables
available
at
our
Service
Centres.
38