Po→Erful Operation; Fresh Air Control; Compressor Preheating - Fujitsu AIRSTAGE ASEH09KHCBN Service Manual

Air conditioner wall mounted type
Table of Contents

Advertisement

7-6. POWERFUL operation
The PO→ERFUL operation starts by pressing PO→ERFUL button on the remote controller.
The indoor unit and outdoor unit operate at maximum power as shown in the table below.
Rotation number of compressor
Fan mode
Horizontal louver setting
Release condition:
• Cooling/Dry
Room temperature ≤ Setting temperature -0.5°C or Operation time has passed 20 minutes.
• Heating
Room temperature ≥ Setting temperature +0.5°C or Operation time has passed 20 minutes.

7-7. Fresh air control

The fan motor for Fresh Air is operated in synchronization with the indoor fan operation as below.

7-8. Compressor preheating

By preheating the compressor, warm airflow is quickly discharged when the operation is started.
• Triggering condition
– 30 minutes after compressor stopped.
– Outdoor unit heat exchanger temperature (Tn)
→hen the jumper wire (JM2) is disconnected:
7-6. PO→ERFUL operation
Cooling
Dry
Heating
Operation
Fan motor
(Indoor unit)
Stop
Operation
Fan motor
(for Fresh Air)
Stop
Tn
-4°C
Tn
5°C
Tn
Off
-2°C
On
Tn
Off
7°C
On
- (04-28) -
Maximum
PO→ERFUL
3
7
7. Various control

Advertisement

Table of Contents
loading

Table of Contents