Fujitsu AIRSTAGE ASEH09KHCBN Service Manual page 149

Air conditioner wall mounted type
Table of Contents

Advertisement

 Model: AOEH12KHCBN
Fan speed is defined by outdoor temperature and rotation number of compressor.
• Outside air temperature zone selection
Cooling
Fan step
Y zone
S-HIGH2
S-HIGH1
1,180
HIGH
1,180
10
9
1,180
8
1,080
7
6
5
4
3
2
1
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,200 rpm
3-2. Outdoor fan control
Outside air
temperature rises
21°C
12°C
2°C
-8°C
Heating
Y zone
1,200
1,200
1,200
1,170
1,170
930
900
840
900
740
780
740
570
710
550
410
430
380
400
380
Outside air
temperature drops
Y zone
Z zone
F zone
G zone
H zone
Dry
Cooling or dry at low outdoor temp.
Z zone
1,180
550
1,080
550
900
500
900
400
780
280
570
280
550
280
430
280
400
280
- (04-15) -
19°C
10°C
0°C
-10°C
F zone
G zone
280
220
280
220
280
220
240
200
210
200
210
200
210
200
210
200
210
200
Unit: rpm
H zone
220
220
220
200
200
200
200
200
200
3. Fan control

Advertisement

Table of Contents
loading

Table of Contents