Troubleshooting Guide - Kidde 30CUAR-V User Manual

Combination photoelectric smoke & carbon monoxide alarm with hardwire interconnect & voice
Table of Contents

Advertisement

Operational Mode
Initiating Alarm
(multiple alarms in an
interconnected system)

4. Troubleshooting Guide

If you require further information please contact Product Support at 1-800-880-6788 or write us at:
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302. Our internet address is www.kidde.com.
Trouble Condition
Visual Indications
False Low Battery
None.
(AC power
connected before
backup batteries
activated)
Low Battery
Amber LED blinks every
60 sec.
Smoke Sensor Fault
Amber LED blinks every
60 sec.
CO Fault
Amber LED blinks 2
times every 60 sec.
Fatal Fault
Amber LED blinks 3
times every 60 sec.
Visual Indications
Red LED blinks in time with
alarm pattern indicating that
this is the unit initiating the
alarm in an interconnected,
multiple alarm, system.
NOTE: It is possible for more
than one unit to detect a haz-
ard and become an initiating
alarm unit (Red LED blinking).
Audible Indications
Chirp and voice "Activate Battery"
every 60 sec. After 1 hour, voice
occurs only once every 15 mins.
Chirp and voice "Low Battery"
every 60 sec. After 1 hour, voice
occurs only once every 15 mins.
After button push, voice "Hush
Mode Activated."
3 chirps every 60 sec and voice
"Smoke Sensor Error." After 1 hour,
voice occurs only once every
15 mins..
3 chirps every 60 sec and voice
"Replace Alarm." After 1 hour, voice
occurs only once every 15 mins.
3 chirps every 60 sec and voice
"Replace Alarm." After 1 hour, voice
occurs only once every 15 mins.
Audible Indications
Unit in either Smoke or CO alarm
mode.
Action/Note
Action
* Pull the battery pull tab to activate the
backup batteries.
* Push button once to silence for 24 hrs.
(Push button again to clear Hush
perform a test.) Note: 7 days after Low
Battery begins, the notifications cannot
be silenced.
* Replace batteries as soon as possible.
* See Cleaning Your Alarm section.
* Push button once to attempt to reset the unit.
* If error continues, remove alarm, dispose
unit, and replace as soon as possible.
* Push button once to attempt to reset the
unit.
* If error continues, remove alarm, dispose
unit, and replace as soon as possible.
* Push button once to attempt to reset the
unit.
* If error continues, remove alarm, dispose
unit, and replace as soon as possible.