45MBCAQ: Installation Instructions

ACCESSORIES

The unit system comes with the following accessories. Use all of the
installation parts and accessories to install the unit. Improper installation
may result in water leakage, electrical shock and fire, or cause the
equipment to fail. The items are not included with the unit must be
purchased separately.
Table 2 — Accessories
Name of Accessory
Manual
Soundproof/insulation sheath
(24K/36K/48K)
Soundproof/insulation sheath
(24K/36K/48K)
Outlet pipe sheath (24K/36K/48K)
Wire tie (24K/36K/48K)
Remote controller
Magnetic ring (9K/12K/18K)
Wireless module cable
Remote controller holder
Drain joint
Seal ring
Brass nut
Tapping screw (24K/36K/48K)
(9K/12K/18K)
Drain clamp (24K/36K/48K)
Conduit installation plate
Batteries
Rubber block (24K/36K/48K)
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Quantity
Image
1
1
1
1
6
1
2
1
1
1
1
2
6
2
2
1
2
1
Optional Accessories
There are two types of remote controls: wired and wireless.
Select a remote controller based on customer preferences and
requirements and install in an appropriate place.
Refer to catalogues and technical literature for guidance on selecting a
suitable remote controller.
Table 3 — Pipe Specification
Name
Model
Liquid Side
9K
Φ1/4 in (Φ6.35mm) Φ3/8 in (Φ9.52mm)
12K
Φ1/4 in (Φ6.35mm) Φ3/8 in (Φ9.52mm)
18K
Φ1/4 in (Φ6.35mm) Φ1/2 in (Φ12.7mm)
Connecting
Pipe
Assembly
24K
Φ3/8 in (Φ9.52mm) Φ5/8 in (Φ16mm)
36K
Φ3/8 in (Φ9.52mm) Φ3/4 in (Φ19mm)
48K
Φ3/8 in (Φ9.52mm) Φ3/4 in (Φ19mm)
NOTE: Panel installation should be performed after wiring and piping have
been completed.

Model Numbers

Table 4 — Model Numbers
Tons
BTUH
0.75/1.00
9/12
1.50
18
2
24
3
36
4
48
Table 5 — Required Accessories
Model
45MBCQ01XXX3
45MBCQ02XXX4
7
Gas Side
Remarks
Pipes are not
included in the
accessories.
They must be
purchased
separately from
the local dealer.
Voltage
Carrier
208/230V
45MBCAQ12---3
208/230V
45MBCAQ18---3
208/230V
45MBCAQ24---3
208/230V
45MBCAQ36---3
208/230V
45MBCAQ48---3
Description
Cassette panel for units 09-18
Cassette panel for units 24-48