Load Factory Defaults - ZyXEL Communications Dimension ES-2108 Support Notes

Es-2108 series
Hide thumbs Also See for Dimension ES-2108:
Table of Contents

Advertisement

Load Factory Defaults

From Web GUI:
1.
Click Management and then Maintenance in the navigator panel to bring
up the following screen.
2.
Click on the "Click Here" button of the Load Factory Defaults to bring up
the following screen.
3.
A dialog pops up with the message "Are you sure you want to load factory
defaults?".
4.
Click OK to go to the following dialog.
5.
Click on the OK button. Now, all switch configurations has been reset to
the factory defaults and the system will be restarted.
6.
Please note that the switch IP address is now 192.168.1.1.
From Console Port:
1.
Connect to the console port and open the Terminal Emulation Software.
2.
Type in the correct password to bring up the prompt.
Type "erase run" to load the factory default configurations.
All contents copyright (c) 2006 ZyXEL Communications Corporation.
ES-2108 Series Switch Support Notes