Note: The wiring diagrams in this guide are included as a reference. The manufacturer has a
policy of continuous product and product data improvement and reserves the right to change
design and specifi cations without notice. Always check the unit nameplate and wiring diagram
for the actual unit requirements.

Wiring Precautions

1. EACH unit should be installed with its own dedicated power supply source. The power source
needs to be sized correctly for the unit capacity.
2. The rated voltage of the unit is as shown in this manual.
3. Before turning on, verify that the voltage is within the 187~252 V range (for 208/230 V, single
phase units).
4. Always use a grounded terminal and install a separate receptacle to supply power to the
air conditioner. For high voltage connections, fl exible electrical conduit is recommended
whenever vibration transmission may create a noise problem within the structure.
5. Use a dedicated breaker and receptacle matched to the capacity of the air conditioner.

Outdoor Wiring Connections

1. Remove the wire clip and connect the power connection wire and signal control wire terminals
according to the color coding.
2. Attach the wires to the terminals and make sure they are securely fastened. Refer to wiring
diagrams in this manual. An example is provided in the fi gure below:
9K-12K
Electrical Notes:
3
2
Indoor unit connection
18K-24K
Handle
1
green
white
(yellow-
(blue)
black
green)
G
1 2
Indoor unit connection
2
3
L1
L2
G
red
black
white
green
(brown)
(brown)
(blue)
(yellow-
green)
3
L1
L2
POWER