SETTING THE SWITCH S101
The minimum temperature limit is set with switches 1 - 5. The maximum temperature limit is set with swit-
ches 6 -10. A temperature limit is set when the switch in question is in the up position (ON). Make sure that
only one switch in each group is in the ON position.
switch
1
|
2
3
4
5
6
7
8
|
9
10
Minimum in °C
1 |
3
6
7
9
Minimum in °F
33.8 | 37.4| 42.8 | 44.6| 48.2
|
Maximum in °C
3
6
|
7
9
10
Maximum
in °F
|
37.4|
42.8! 44,6 | 48.2 |
50
The maximum temperature must always be set at least 2°(3.6°F) higher than the minimum temperature.
The limits marked in the table of +1°C (+33.8°F) and +7°C (+44.6°F) (switches 1 and 8) are preset at the fac-
tory. This setting results in a set point temperature of +4°C (+39.2°F).
IF THE FACTORY SETTINGS FOR SWITCH S101 HAVE TO BE ALTERED, CHECK TO MAKE SURE THAT
THE SET TEMPERATURES ARE REACHED IN THE APPLIANCE.