AT COMMANDS (continued)
\Nn
Error Control Mode
\N0
Buffer Mode. Modem does not use error
control; DTE rate can differ from VF rate.
\N1
Direct Mode. Modem does not use error
control; DTE rate and VF rate must be
the same.
\N2
MNP or Disc. Modem disconnects if it
does not connect in MNP mode.
\N3
MNP or Buffer. Modem connects in
Buffer mode if it does not connect in MNP
mode.
\N4
V.42/MNP or Disc. Modem disconnects if
it does not connect in V.42 or MNP mode.
\N5
V.42/MNP or Buffer. Modem connects
in Buffer mode if it does not connect
in V.42 or MNP mode.
\N6
LAPM or disconnect.
\N7
LAPM or buffer.
\Qn
Flow Control of DTE
\Q0, \Q5, \Q6
Disables flow control of DTE.
\Q1, \Q4
Enables XON/XOFF flow control.
\Q2, \Q3
Modem raises and lowers CTS to start
and stop flow control.
\Qn
Flow Control of Modem
\Q0, \Q2, \Q4
Disables flow control of modem.
\Q1, \Q5
Enables XON/XOFF flow control.
\Q3, \Q6
Modem starts and stops flow control
based upon state of DTE's RTS signal.
\Tn
No Data Disconnect Timer
\T0
Disables no data disconnect timer.
\Tn
Sets no data disconnect timer to a value
from 1 minute to 255 minutes.
\Xn
XON/XOFF Passthrough
\X0
Disables transmission of flow control
characters to remote modem.
\X1
Enables transmission of flow control
characters to remote modem.
%A n
Sets error control fallback character n to
an ASCII value from 0 to 127.
%B n
Sets data rate to n (300 to 19200).
%Cn
MNP 5 Data Compression
%C0
Disables MNP5 data compression.
%C1
Enables MNP5 data compression.
%R n
Sets DTE rate to n (300 to 115200).
I Hn
V.42 bis Data Compression
IH0
Disables V.42bis data compression.
IH1
Enables V.42bis data compression for
transmit only.
IH2
Enables V.42bis data compression for
receive only.
IH3
Enables V.42bis data compression
in both transmit and receive.

RESULT CODES

Numbers(1) Numbers(2) Words
0
0
1
1
2
2
3
3
4
4
Result Codes 5–14, 16, 19 are enabled with the X1,
X2, X3, and X4 commands.
5
5
6
6
7
7
8
8
10
10
11
11
12
12
13
16
14
13
15
14
16
15
17
17
19
19
Result Codes 20–27 are enabled with the X5
command (EC suffix) or the X6 command (V.42 or
MNP suffix).
20
10
21
11
22
12
23
16
24
13
25
17
26
15
27
5
29
14
Result Codes 15, 28–34 are enabled with the X7
command (DTE rate suffix).
28
28
30
30
32
32
34
34
DIAL COMMAND MODIFIERS
T
Tone Dial (DTMF)
P
Pulse Dial
,
Pause
W
Wait for Dial Tone
R
Reverse Dial
@
Quiet Answer
!
Hook Flash
;
Return to Command Mode
12
OK
CONNECT
RING
NO CARRIER
ERROR
CONNECT 1200
NO DIALTONE
BUSY
NO ANSWER
CONNECT 2400
CONNECT 4800
CONNECT 9600
CONNECT 12000
CONNECT 14400
CONNECT 19200
CONNECT 7200
CONNECT 16800
CONNECT 300
CONNECT 2400/EC
CONNECT 4800/EC
CONNECT 9600/EC
CONNECT 12000/EC
CONNECT 14400/EC
CONNECT 16800/EC
CONNECT 7200/EC
CONNECT 1200/EC
CONNECT 19200/EC
CONNECT 38400
CONNECT 57600
CONNECT 76800
CONNECT 115200

Advertisement