Determening Sensor Data; Step 1: Transducer Wiring - Siemens SITRANS FSS100 Installation Manual

Ultrasonic flowmeters
Table of Contents

Advertisement

a
b
c
d
5.10.2.3

Determening sensor data

Step 3: Determining sensor data
Several sensor dimensions must be accurately measured to maximize the accuracy of the flow
measurement.
Note
Inaccuracy in sensor measurement may lead to flow error.
To help with the installation precision, see Sensor geometry measurement reports
(Page 87). Use it to write measured value into the appropriate field and populate the
transmitter wizard with these measurements afterwards.
5.10.3

Step 1: Transducer wiring

Electrical connection of transducer
1. Remove the lid of the terminal housing.
2. Connect the wire without a spade terminal to
3. Connect the wire with a spade terminal to
4. Connect the wire of the transducer coax cable to
SITRANS FSS100
Installation Manual, 12/2023, A5E52595000-AA
=
Concrete pipe
=
Repair mortar
=
Mandrel
=
Transducer holder
5.10 Installation instructions
Transducer cut-away
.
(the transducer housing).
.
Installing/mounting
57