5-2. Outdoor unit

¢ Heatsink thermistor
 Models: AOUH24LUAS1, AOUH30LUAS1, and AOUH36LUAS1
Temperature °F (°C)
-22.0 (-30.0)
-12.0 (-25.0)
-4.0 (-20.0)
5.0 (-15.0)
14.0 (-10.0)
23.0 (-5.0)
32.0 (0.0)
41.0 (5.0)
50.0 (10.0)
59.0 (15.0)
68.0 (20.0)
77.0 (25.0)
86.0 (30.0)
95.0 (35.0)
104.0 (40.0)
113.0 (45.0)
122.0 (50.0)
131.0 (55.0)
140.0 (60.0)
149.0 (65.0)
158.0 (70.0)
167.0 (75.0)
176.0 (80.0)
185.0 (85.0)
194.0 (90.0)
203.0 (95.0)
212.0 (100.0)
5-2. Outdoor unit
Resistance (kΩ)
94.26
67.95
49.62
36.68
27.42
20.73
15.83
12.21
9.50
7.46
5.90
4.71
3.78
3.06
2.50
2.05
1.69
1.40
1.17
0.98
0.83
0.70
0.60
0.51
0.44
0.38
0.33
- (03-64) -
Voltage (V)
0.08
0.11
0.15
0.20
0.26
0.34
0.43
0.55
0.68
0.84
1.01
1.21
1.42
1.64
1.88
2.11
2.35
2.58
2.81
3.02
3.22
3.41
3.58
3.73
3.87
3.99
4.10