5
SERVICE
TO GAIN ACCESS TO VALVE FOR SERVICING
Turn off hot and cold water
CAUTION
supplies before beginning.
• Remove HANDLE (see step 3 and reverse).
• Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).
VALVE LEAKS WHEN SHUT OFF
• Remove CARTRIDGE, see STEP 1 and STEP 2 and REVERSE process.
• Clean SEALS on the side of CARTRIDGE. Clean inside sealing surface of VALVE BODY.
• Re-assemble CARTRIDGE. Install trim. Turn on water supply and check for leaks.
REPLACING CARTRIDGE (FIGURE 1)
• To remove CARTRIDGE (1) , install split WASHER (3) (only supplied with replacement cartridge). as shown.
• Proceed to unthread BONNET NUT (2) counter clockwise.
Note: CARTRIDGE (1) should be pulling out while unthreading BONNET NUT (2).
Upon removal of the old Cartridge, install a new cartridge and secure it with
BACK TO BACK INSTALLATION (FIGURE 2, 3 & 3A)
• Remove CARTRIDGE (1).
• Remove venturi tube by pushing it out. As shown in FIGURE 3.
• Rotate CARTRIDGE (1)) 180˚ so that the Up text is displayed on the bottom side. As shown in FIGURE 2.
• Reinstall the venturi tube by pushing it in. As shown in FIGURE 3A.
• Insert Cartridge back into the valve.
• Reassemble BONNET NUT (2). and hand tighten.
Figure 1.
6

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
3
2
1
PUSH UP
Figure 3.
BONNET NUT
Standard
Figure 2.
PUSH DOWN
Figure 3A.
- 4 -
(Hand tighten).
Back to Back
M965471 Rev. 1.3 (4/18)