Devices On Din Rail - Siemens SICHARGE UC Panto Kit Repair Instructions

Table of Contents

Advertisement

Power box repair cases

7.2 Devices on DIN rail

7.2
Devices on DIN rail
Location of the devices
Figure 7-2
Device tag
Part number
-BT01
L2D0091070
-EB02
8MR2130-3BA
-FC03, -FC04 L2D0097590
-FA02
L2D0098080
-KF01
L2D0091190
Instructions
1. Label the cable(s) with the connected contact(s) or take a photo if sufficient.
2. Disconnect the cable(s) from the device.
3. Remove the device from the DIN rail.
4. Replace it with a new device and insert the new one on the DIN rail.
5. Reconnect the cable(s) to the same terminals as before, according to the picture or label.
6. Restart the system and test the exchanged device.
32
Devices on DIN rail
Quantity Designation
1
THERMISTOR NTC 4.7KOHM SERIES 3950 K SCREW B57045K
1
HEATER
2
5026806.100 - FUSE 100A
1
952565 - DG M YPV 1200 FM - SPD Type 2 1200V DC
1
Thermostat KTO 011, NC, 0-60°C