Displayed
Possible cause
code
The sub PCB sensor is open
when the oven is operating.
C-22
There is a short in the sub PCB
sensor.
The temperature probe sensor
is short when the oven is
C-23
operating.
The main PCB sensor is open
when the oven is operating.
C-30
There is a short in the main PCB
sensor.
This code occurs if the PCB
C-31
temperature rises abnormally
high.
This error message appears
Bad line
if the power cord is installed
improperly.
This code occurs if the sub PCB
C-A2
temperature rises abnormanlly
high.
Solution
Press Off, and then restart the
oven. If the problem persists,
disconnect all power to the
range for at least 30 seconds
and then reconnect the power.
If this does not solve the
problem, call for service.
Call for service
If the power connection is
plugged in improperly, that
code appears on the display.
Reconnect the power
connection properly, and the
message disappears.
Press Off.
Check the oven vent and
cooling vent. If the vent is
closed, never block the vent
by anything. After cooling the
oven, restart the oven.
If this does not solve the
problem, call for service.
COOKTOP
Displayed
Possible cause
code
This code occurs if
communication between the
F0
Main and Inverter PBA is
interrupted.
The top sensor is open when the
burner is operating.
C0
The top sensor is short when
the burner is operating.
The IGBT sensor is open when
the burner is operating.
C2
The IGBT sensor is short when
the burner is operating.
This code occurs if the DC fan
A2
motor is open or locked.
Solution
Power Off, and then Power On
to the setting you want again.
If the problem persists,
disconnect all power to the
range for at least 30 seconds
and then reconnect the power.
If this does not solve the
problem, call for service.
Call for service
English 69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nsi6db990012/acNsi6dg9900sr/ac

Table of Contents