MEASURING DATA
Fx
70
Agreements:
All Level, Frequency Response and Distortion Measurements are performed with "AUDIO PRECISION
SYSTEM ONE". Generator impedance 25 ohms, Analyzer impedance 100 kohms.
Levels measured with f=1 kHz.
The noise levels measured at the outputs refer to the nominal output level of +18dBm.
Tolerances of the level values: +/-1 dB.
All Distortion measurements are performed with a measurement bandwidth of 10 Hz - 22 kHz, without filter.
Measured is THD+Noise.
Measurements at the original signal with EFFECT OFF.
0 dBu = 775 mV rms
Operating voltage and current are measured with "PHILIPS MULTIMETER PM 2517X".
Power Consumtion is measured with "Zares Wattmeter".
Recall of the Service Presets: see table service functions Fx 70 (page 48) and service presets (page 50)
Note:
For operation of some functions (e.g. storing of programs) and explanation of parameter
functions the operating manual is necessary.
1.
Operating voltage
EB(V)
90-250 Vac f = 50 -60 Hz
2.
Operating current
IB(a)
at 110 Vac
150 mA
at 230 Vac
110 mA
3.
Power consumption
at 110 Vac
10.5VA
at 230 Vac
12.5 VA
4. Inputs
- both inputs connected (Stereo operation)
4.1. Input impedance
4.2. Input voltage
- Input control fully to the right
- recall service preset 01
- input level switch position HI.
Level indication = 0 dB
Level indication = CLIP
- input level switch position LO.
Level indication = 0 dB
Level indication = CLIP
Ei
= 95 mV * -18dBm
Eimax
= 175mV «-12dBm
Zi
50 kohms
6
Eimax
775 mV = OdBm
1.55 V = +6dBm