Installation Of New Refrigerant Air Conditioner - Toshiba MMY-MAP0806FT8P-E Installation Manual

Air conditioner (multi type)
Hide thumbs Also See for MMY-MAP0806FT8P-E:
Table of Contents

Advertisement

Part name
MAP080
MAP120 MAP140 MAP160
MAP100
Attached pipe
(Ø12.7 for draw-out
1
forward)
Attached pipe
(Ø12.7 for draw-out
1
downward)
Attached pipe
(Ø15.9 for draw-out
forward)
Attached pipe
(Ø15.9 for draw-out
downward)
Attached pipe
(Ø19.1 for draw-out
forward)
Attached pipe
(Ø19.1 for draw-out
downward)
Attached pipe
(Ø9.5 for draw-out
1
forward)
Attached pipe
(Ø9.5 for draw-out
1
downward)
Attached pipe
(Ø9.5 for draw-out
1
forward)
Attached pipe
(Ø9.5 for draw-out
1
downward)
Safety Manual
1
1
3-EN
Q'ty
Shape
MAP180
MAP200
Liquid pipe
1
1
Ø15.9 Ø12.7 pipe fitting
* Flare the connector
on the outdoor unit for
installation.
1
1
1
1
Liquid pipe
* Flare the connector
on the outdoor unit for
installation.
1
1
Liquid pipe
1
1
Ø15.9 Ø19.1 pipe fitting
* Flare the connector
on the outdoor unit for
installation.
1
1
Liquid pipe
Ø12.7 Ø9.5 pipe fitting
* Flare the connector
on the outdoor unit for
installation.
Liquid pipe
Ø15.9 Ø9.5 pipe fitting
* Flare the connector
on the outdoor unit for
installation.
For hand over directly
1
1
1
to the customer.
2

Installation of new refrigerant air conditioner

This air conditioner adopts the new HFC refrigerant (R410A) which does not deplete the ozone layer.
R410A refrigerant is vulnerable to impurities such as water, oxidizing membranes, or oils because the pressure
Usage
of R410A refrigerant is higher than that of the former refrigerant by approximately 1.6 times.
As well as the adoption of the new refrigerant, the refrigerating oil has been also changed. Therefore, pay
attention so that water, dust, former refrigerant, or refrigerating oil does not enter the refrigerating cycle of the
new refrigerant air conditioner during installation.
To prevent mixing of refrigerant or refrigerating oil, the size of the charge port of the main unit or connecting
section of the installation tool differs to that of an air conditioner for the former refrigerant.
Accordingly, exclusive tools are required for the new refrigerant (R410A) as shown below.
For connecting pipes, use new and clean piping materials so that water or dust does not enter.
Required tools and cautions on handling
It is necessary to prepare the tools and parts for installation as described below. The tools and parts which will be
newly prepared in the following items should be restricted to exclusive use.
Explanation of symbols
: Newly prepared (It is necessary to use it exclusively with R410A, separately from those for R22 or R407C.)
: Former tool is available.
U
s
e
d
o t
Gauge manifold
Charging hose
Charging cylinder
Gas leak detector
Vacuum pump
Vacuum pump with counterflow
F
a l
e r
o t
l o
B
e
n
d
r e
Refrigerant recovery device
Torque wrench
P
p i
e
c
u
t t
r e
Refrigerant canister
Brazing machine/Nitrogen gas
cylinder
Refrigerant charging balance
– 2 –
o
s l
U
s
a
g
e
Vacuuming, charging refrigerant
and operation check
Charging refrigerant
Unusable (Use the Refrigerant charging balance.)
Checking gas leak
Usable if a counter-flow preventive adapter is
Vacuum drying
attached
Vacuum drying
F
a l
e r
p
o r
c
e
s s
n i
g
f o
p
p i
e
s
B
e
n
d
n i
g
p
o r
c
e
s s
n i
g
f o
p
p i
e
s
Recovering refrigerant
Tightening flare nut
C
u
t t
n i
g
p
p i
e
s
Charging refrigerant
Brazing of pipes
Charging refrigerant
P
o r
p
r e
u
s
e
f o
o t
o
s l
p /
r a
s t
Exclusive to R410A
Exclusive to R410A
Exclusive to R410A
R22 (Existing article)
Usable by adjusting size
R22 (Existing article)
Exclusive to R410A
Exclusive to Ø12.7 mm and Ø15.9 mm
R22 (Existing article)
Exclusive to R410A
Enter the refrigerate name for identification
R22 (Existing article)
R22 (Existing article)
EN
ID
ID
4-EN

Advertisement

Table of Contents
loading

Table of Contents