1. PCB TEST
Step Press Button What was Tested
1
All LED LED of each button will be on one by one, Heater will brew on, (heater temperature >75C will switch off). CARRAFFE IS
Timer
NEEDED!
Set
All LED switch off, LED screen will display AD value of rotary switch, turn lever to coffee position, LED screen display " 00C",turn lever
2
to hot water position LED screen display "00A",
3
LED screen display 004,PTC,electromagetic valve, pump will all switch on, when open lid, LED screen will display LID.
Clock
4
Over Ice
LED screen display 005,PTC,electromagetic valve, pump will all switch off.
5
Mild
LED screen display Pa1,(test water NTC open or short).
6
Gold
LED screen display Pa2,(test PTC NTC open or short).
7
Strong
LED screen display Pa3,(test heater NTC open or short).
8
Temp „-"
LED screen display 06.
9
Temp „+"
LED screen display 07.
10
Water
LED screen display 08.
11
Calc
LED screen display Pas,(test rotary switch open or short).
12
Power
cancel PCB test mode.