Vitotrol 100, Type Utdb-Rf; Vitotrol 100, Type Utdb-Rf2; Part No. Z007695; Part No. 7296064 Vitotrol 100, Type Utdb-Rf2 - Viessmann VITODENS 050-W Technical Manual

Gas condensing boilers
Table of Contents

Advertisement

Control unit
(cont.)
8 0
Specification, room temperature controller
Rated voltage
Transmission frequency
Transmission
Range
IP rating

Vitotrol 100, type UTDB-RF

Part no. 7296064
■ Room thermostat with integral wireless transmitter and separate
receiver with 1 switching output for central heating and DHW heat-
ing (same switching times)
■ With analogue time switch
Vitotrol 100, type UTDB-RF

Part no. Z007695

■ Room temperature controller with integral wireless transmitter and
separate receiver with switching output (2-point output)
■ With menu-guided operation
■ With digital time switch

Vitotrol 100, type UTDB-RF2

Part no. Z011486

6
Room temperature controller with integral wireless transmitter and
wireless receiver for installation in the control unit support
■ With digital time switch
■ With individual day and seven-day program
■ Operation with user prompts:
– 3 preselected time programs, individually adjustable
– Constant manual mode with adjustable set room temperature
– Frost protection mode
– Holiday program
■ With selector keys for party and economy mode
Installation in the main living room on an internal wall opposite radia-
tors. Never install inside shelving units, in recesses, or immediately
by a door or heat source (e.g. direct sunlight, fireplace, TV set, etc.).
Operation independent of mains power supply
Wireless receiver with relay state indication.
VIESMANN
56
1 3
0
3 V–
868 MHz
< 10 mW
approx. 25 to 30 m inside buildings,
subject to construction
IP 20 to EN 60529
Ensure through design/installation
Function type
RS type 1B to EN 60730-1
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
–25 to +65 °C
Setting range
– Comfort temperature
10 to 40 °C
– Setback temperature
10 to 40 °C
– Frost protection temper-
ature
5 °C
Power reserve during bat-
tery change
3 min
Specification, receiver
Operating voltage
230 V~ ± 10 % 50 Hz
Rated breaking capacity of the floating contact
– max.
6(1) A, 230 V~
– min.
1 mA, 5 V–
IP rating
IP 20 to EN 60529
Ensure through design/installation
Safety category
II to EN 60730-1 subject to correct in-
stallation
Permissible ambient temperature
– Operation
0 to +40 °C
– Storage and transport
–25 to +65 °C
■ With individual day program
■ With room thermostat, 3 V battery operation, receiver to be instal-
led in the control unit
■ With individual day and seven-day program
■ With 3 preset time programs, individually adjustable
■ Room temperature controller with 3 V battery operation, receiver
with 230 V mains voltage
8 0
Specification, room temperature controller
Rated voltage
Transmission frequency
Transmission
Range
IP rating
Function type
3 V–
2 LR6/AA batteries
868 MHz
< 10 mW
Approx. 25 to 30 m inside
buildings, subject to construc-
tion
IP 20 to EN 60529; ensure
through design/installation
RS type 1B to EN 60730-1
VITODENS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 100-wB0haB0kaBpkaB1ga

Table of Contents