Separate DHW cylinders for Vitodens 050-W
Dimensions of type CVB, 300 l capacity
VA
ELH
R
KW/E
362
714
E
Drain
ELH
Immersion heater
HR
Heating water return
HR
Heating water return, solar thermal system
s
HV
Heating water flow
HV
Heating water flow, solar thermal system
s
KW
Cold water
R
Inspection and cleaning aperture with flange cover (also suit-
able for installation of an immersion heater)
SPR1 Clamping device for securing immersion temperature sen-
sors to the cylinder jacket, with fixing points for 3 immersion
temperature sensors
SPR2 Clamping device for securing immersion temperature sen-
sors to the cylinder jacket, with fixing points for 3 immersion
temperature sensors
TH
Thermometer (accessories)
VA
Protective magnesium anode
DHW DHW
Z
DHW circulation
DHW performance data at rated heating output
Rated heating output
for DHW heating
Continuous DHW output
For DHW heating from 10 to 45 °C and an
average boiler water temperature of 78 °C
VITODENS
DHW
HV/SPR
Z
HR
HVs/SPR
HRs
SPR
kW
kW
l/h
(cont.)
Recommended positioning of the cylinder temperature sensor
for solar operation
A Cylinder temperature sensor
(solar control unit)
B Threaded elbow with sensor well
(standard delivery)
Pressure drop on the DHW side
100
10
80
8
60
6
50
5
40
4
30
3
20
2
10
1
8
0.8
6
0.6
5
0.5
4
0.4
3
0.3
DHW flow rate
in l/h
A 300 l capacity
17.5
17.5
425
A
23.0
23.0
555
VIESMANN
3
29.3
26
638
27