Control unit
(cont.)

6.2 Specification - control unit

Rated voltage
230 V~
Rated frequency
50 Hz
Rated current
4 A
Protection class
I
Permissible ambient temperature
- Operation
Frost-free, dry and heated room
- Storage and transport
-20 to +65 °C
Electronic temperature
limiter setting (heating
mode)
91 °C (cannot be altered)
Setting range for DHW
temperature
10 to 60 °C
Setting range for heating
curve
Slope
0.2 to 3.5
Level
-13 to 40 K
TCU communication
module (integral)
WiFi frequency band
2400 - 2483.5 MHz
Max. transmitting power
+ 17 dBm
Zigbee frequency band
2400 - 2483.5 MHz
Max. transmitting power
+ 10 dBm
Supply voltage
24 V
Power consumption
4 W

6.3 Accessories for control unit

Overview of control accessories
Accessories
Part no. 7141709
Vitotrol 100, type UTA
Part no. 7170149
Vitotrol 100, type UTA-RF
Part no. 7454521
Vitotrol 100, type UTDB
Part no. Z007691
Vitotrol 100, type UTDB
Vitotrol 100, type UTDB-RF
Vitotrol 100, type UTDB-RF
Part no. Z011244
Analogue time switch
Outside temperature sensor
Part no. Z006506
VITODENS
Vitodens 050-W
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Vitodens 100-W
X
X
X
X
X
X
X
X
VIESMANN