Panasonic EYFLF1XA Operating Instructions Manual page 75

Cordless impact driver / cordless impact wrench
Hide thumbs Also See for EYFLF1XA:
Table of Contents

Advertisement

Available languages

Available languages

[EYFLF]
Cross thread reduction function
The tool reverses approximately 360° or 180°
before moving forward to align the threads
and reduce cross-threading.
1. Set the tool to setting configuration mode.
(See page 71.)
2. Press the D button once.
The cross thread reduction function set-
ting value will be displayed.
[Fig.21]
3. Press the
and
setting to ON or OFF.
Display
R0
R1
R2
4. Press the OK button to accept the new
setting.
[EYFLF]
Rundown error detecting function
The rundown error detecting function caus-
es a red indicator to flash if work ends more
quickly than a set time, for example due to
retightening of a previously tightened fastener
or binding of the screw's thread.
1. Set the tool to setting configuration mode.
(See page 71.)
2. Press the B button twice.
The rundown error detecting function set-
ting value will be displayed.
[Fig.22]
3. Press the
and
time as desired.
Buttons
Display
4. Press the OK button to accept the select-
ed setting.
When the cross thread reduction function
is ON, the set time will be counted after
the tool operates in reverse for approxi-
mately 360°.
buttons to change the
Function
OFF
360° reverse rotation
180° reverse rotation
buttons to change the
Seconds
30
3
1
0.1
0
OFF
[EYFLF]
Tightening time reminder
The tool is locked when it reaches the set
tightening time, and the main unit stops oper-
ation. This feature is convenient for regular
inspection of the tool performance.
1. Set the tool to setting configuration mode.
(See page 71.)
2. Press the C button twice.
The setting value will be displayed.
3. Press
and
change the time.
Operation
4. Press the OK button to accept the new
setting.
NOTE:
• When the remaining time prior to the
tightening time is less than 1 hour, the
display will alternate between the "set
value" and "-1".
If the current tightening time remains
unchanged and the inspection duration
is extended, the new set value must be
greater than the current one.
When it reaches the set time, the display
alternates between the set value and 0.
[EYFLF]
Buzzer setting
You can select from three buzzer modes.
1. Set the tool to setting configuration mode.
(See page 71.)
2. Press the A button twice.
The current setting value will be displayed.
3. Press the
desired value.
Display
b0
b1
Buzzer accompanying green indicator
b2
Buzzer accompanying red indicator
4. Press the OK button to accept the new
setting.
NOTE:
The tool ships with the buzzer mode set to
b0 by default.
‒ 73 ‒
buttons as required to
Display Tightening time
99
99 hours
1
1 hour
0
OFF
and
buttons to set the
Function
No buzzer
EN

Advertisement

Table of Contents
loading