User Interface Alerts
Fig. 36 Interface Alert Examples
Interface Display
Alert Type 1
Clean and Sanitize
Filter Replacement Required
Low Water
Alert Type 2
Empty Drip Tray
Alert Type 3
Internal Water Leak Detected
26
Champion Dispenser and Ice Machine - 230 V
Condition
Maximum 6 month maintenance
required (Adjustable 1 to 6 months)
Maximum 6 month filter replacement
required (Adjustable 1 to 6 months)
Reservoir sensors are not detecting
water
Drip tray full of water contacting tray
sensors
Unit has internal water leak contacting
chassis sensors
Remedy
Follow PM cleaning procedure in
service manual and reset timer
Verify water is turned "ON" and internal
filter has been installed. If this does not
correct problem, unit will need to be
serviced
Empty drip tray, dry tray/terminals and
reinstall
§ Dry chassis, locate leak and repair
§ Reset from user interface menu
(Follett,
, Follett), Service ➔
Advanced ➔ enter access code ➔
Control Board Reset ➔ yes ➔
§ Or, reset control board manually by
pressing reset button