3-wire power supply cord (not
supplied)
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a 3-conductor
power supply cord NEMA 10-30 type SRDT
rated at 240 volt AC minimum,
30 amp, with 3 open end spade lug
connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 3-wire cord connection
instructions see "Electrical connection
(non-Canada) - 3-wire cord" in Electrical
Installation section.
OUTLET RECEPTACLE - NEMA 10-30R
receptacle to be located so the power
supply cord is accessible when the dryer is
in the installed position.
GROUNDING CONNECTION - See
"Grounding requirements" in Electrical
Installation section.
4-wire power supply cord
(not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor
power supply cord NEMA 14-30 type SRDT
or DRT (as required) rated at 240 volt AC
minimum, 30 amp, with 4 open end spade
lug connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 4-wire cord connection
instructions see "Electrical connection
(non-Canada) - 4-wire cord" in Electrical
Installation section.
NOTE
Dryers manufactured for sale in Canada
have factory-installed, 4-wire power
supply cord (NEMA 14-30).
OUTLET RECEPTACLE - NEMA 14-30R
receptacle to be located so the power
supply cord is accessible when the dryer is
in the installed position.
GROUNDING CONNECTION - See
"Grounding requirements" in Electrical
Installation section.
PRE-INSTALLATION REQUIREMENTS
Electrical requirements for
gas dryer:
CIRCUIT - Individual, properly polarized and
grounded 15 amp. branch circuit fused with
15 amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120
volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - Dryer is equipped with
120 volt 3-wire power cord.
GROUNDING CONNECTION - See
"Grounding requirements" in Electrical
Installation section.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
Grounding type wall receptacle
Power cord with
3-prong grounded plug
Gas supply requirements
WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when
subjected to natural gas, causing gas leaks.
Use ONLY black iron, stainless steel, or
plastic-coated brass piping for gas supply.
11
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.

Advertisement